Independent Suture Tape Reinforcement of Small and Standard Diameter Grafts for Anterior Cruciate Ligament Reconstruction: A Biomechanical Full Construct Model

Authors: Samuel Bachmaier, Patrick A Smith, Jordan Bley, Coen A Wijdicks

Journal: Arthroscopy
Publication year: 2018

DOI: 10.1016/j.arthro.2017.10.037

IBISG Summary

This laboratory study examined whether independent suture tape reinforcement improves the mechanical performance of small and standard-diameter soft-tissue grafts used for ACL reconstruction. Tripled small-diameter and quadrupled standard-diameter graft constructs were tested with and without suture tape reinforcement under cyclic loading and load-to-failure conditions.

Key Findings

Suture tape reinforcement reduced dynamic elongation in both small and standard-diameter grafts. At the higher 400 N loading level, elongation was reduced by 50% in the small grafts and 26% in the standard grafts. Reinforcement increased ultimate failure load by 64% for small grafts and 40% for standard grafts, with no significant mechanical difference between the two reinforced constructs.

Why This Research Matters

Smaller soft-tissue grafts may be more vulnerable to stretching or failure following ACL reconstruction. This study suggests that independently fixed suture tape can act as a protective safety belt, reducing graft elongation and increasing construct strength without completely shielding the graft from load. However, these laboratory results do not demonstrate that reinforcement reduces graft failure or improves clinical outcomes in patients.