Tape Suture Constructs for Instabilities of the Pubic Symphysis: Is the Idea of Motion Preservation a Suitable Treatment Option? A Cadaver Study
Authors: Adrian Cavalcanti Kußmaul, Fanny Schwaabe, Manuel Kistler, Maximilian Jörgens, Korbinian F. Schreyer, Axel Greiner, Wolfgang Böcker, Christopher A. Becker
Journal: Archives of Orthopaedic and Trauma Surgery
Publication year: 2023
DOI: 10.1007/s00402-022-04547-6
IBISG Summary
This cadaveric biomechanical study investigated whether a flexible tape suture construct could stabilise disruption of the pubic symphysis while preserving physiological movement. Symphyseal instability was created in nine cadaveric anterior pelvic rings, which were then stabilised using a criss-cross tape suture technique. The constructs underwent short- and long-term cyclic loading in vertical and horizontal directions.
Key Findings
The tape suture constructs provided sufficient biomechanical stability without exceeding the normal physiological movement of approximately 2 mm at the pubic symphysis. The constructs retained controlled micro-mobility and remained stable during long-term cyclic loading, with no implant loosening or failure. These findings suggest that flexible fixation may stabilise the injured joint without creating the rigid, artificial fusion associated with symphyseal plating.
Why This Research Matters
Traditional plate fixation of pubic symphysis disruption requires extensive surgery and restricts the natural movement of the joint, with implant failure remaining a recognised concern. A minimally invasive tape suture construct could provide stability while preserving controlled physiological motion. This cadaveric study offers encouraging biomechanical evidence, although clinical studies are required to establish its safety, effectiveness and long-term outcomes in patients.